Product Description
Applicable standards
Standard Test Method for High Strain Dynamic Testing of Deep Foundations ASTM D4945-12
Technical Code for Detection of Building Foundation Pile JGJ 106-2014
Dynamic Testing Technology Regulations on Highway Engineering Foundation Pile JTG/T F81-01-2004
Non destructive Detection Code for Railway Engineering Foundation Pile TB 10218-2008
Working Principle:
The tester will provide prediction on the pile bearing capacity, pile integrity, driving stresses and hammer performance for a given pile penetration. It is a relative low cost type of pile testing compared to static load test (MLT or CRP). The testing technique is quick and accurate.
The tester also can be used to perform high strain pile bearing monitoring (HSPBM-Monitoring) to evaluate pile driving information for pile bearing capacity, pile integrity, driving stresses and transferred energy against pile penetration. The results are essential for the actual pile driving process and to obtain valuable data on the hammer, pile & soil system for re-design on the piled foundation (if necessary).
Model | GD-PDT(B) High Strain |
Display method | 8.4-inch true-color LCD screen Resolution: 800×600 (adjustable backlight) |
Storage capacity | 16G electronic hard disk |
Master control system | Low power embedded system Basic frequency≥1GHz Memory: 512M |
Sampling interval | High strain: 10-500μs multi-level adjustable Low strain: 5-1000μs continuous adjustable |
Floating point magnification | 1~256 |
Recording length | 1k |
A/D conversion accuracy | 24-bit instantaneous floating point |
System noise voltage | <20μV |
Dynamic range | ≥100dB |
Data export method | USB |
Frequency bandwidth | 2~12000Hz |
Sensor bandwidth | 0.5~9000Hz |
Power supply mode | Removable lithium battery; desktop charger is supported Service life≥8h |
Operation mode | Touch screen |
Number of channels | High strain: four channels Low strain: one channel |